Page updated · Independent public directory · Last reviewed November 16, 2026 · Not a government agency · By Bill Dahlstrom

How to Read a Water Test Report

Find the Result column, check the unit beside it, and compare the number with the limit on the same line: nitrate at 4.2 mg/L is under EPA's limit of 10 mg/L, and lead at 0.015 mg/L is the same as 15 ppb. ND, or a number after a "<" sign, means the lab did not find it at or above its reporting limit, the smallest amount its equipment can see.

The rest of this page walks a report from left to right, then reads a sample report line by line. Have your own report? Type each number into the results checker.

The columns

Labs name and order their columns a little differently, but most reports carry these.

Test, parameter, or analyte
What the lab looked for: nitrate, lead, total coliform bacteria.
Result
"The Result column shows how much was in your water sample."1
Units
"Be sure to look at the units when comparing them to the health limits - 1 milligram (mg/L) equals 1,000 micrograms (ug/L) and that makes a big difference!"1 The units section below converts each one.
Limit, MCL, or standard
The number your result is compared with. Some labs print EPA's limit, some their state's, and some leave it off.
Reporting limit (RL)
"The Reporting Limit column tells you the smallest amount of something that the lab equipment can see. This is not your result or the health limit."1 Some reports also print an MDL, the method detection limit, the lowest level the lab's equipment could detect at all.2
Flag or qualifier
"The Flag (or sometimes High) column may have a marker show up if your result for that test is over the EPA's health limit or recommended amount."1 Letters such as U, J, and B are qualifiers, explained below.
Method
"The Method column shows which EPA-approved steps the lab used for each test."1

Results with no number

  • ND, or a "<" sign. "Sometimes you might see the letters 'ND' for 'Not Detected' or a number with a 'less than' sign in front (like in the example). This means that the amount was too small to be seen by the equipment, or possibly not there at all."1 Look at the reporting limit on that line. If it is above the limit you care about, ND does not answer the question, and the lab may have a more sensitive method.
  • Present or absent. "Some tests, like Total Coliform Bacteria and E.coli, will only show up as Present/Positive or Absent/Negative."1 Present means the lab found at least one. Read the coliform page or the E. coli page for what to do.

Qualifiers

The New York State Department of Health defines the three you will see most:

U
"The chemical was not detected at a level greater than the method detection limit, or is non-detect."2
J
"The chemical was detected at a level greater than the method detection limit but less than the reporting limit."2 So the lab saw it, but the number is an estimate.
B
"The chemical was detected in a blank sample and the sample result may be biased high."2

Other letters exist. "Laboratories do not all use the same abbreviations, so it is important to check the list included in the report."3

Limit terms

MCL (maximum contaminant level)
"The highest level of a contaminant that is allowed in drinking water. MCLs are set as close to MCLGs as feasible using the best available treatment technology and taking cost into consideration. MCLs are enforceable standards."4
MCLG (maximum contaminant level goal)
"The level of a contaminant in drinking water below which there is no known or expected risk to health. MCLGs allow for a margin of safety and are non-enforceable public health goals."4
Action level
Used for lead and copper. "If more than 10% of tap water samples exceed the action level, water systems must take additional steps."4 It is a trigger for a water system, measured across many homes, not a pass or fail line for one tap.
TT (treatment technique)
"A required process intended to reduce the level of a contaminant in drinking water."4
SMCL (secondary maximum contaminant level)
The limits for iron, manganese, pH, and other taste and stain problems. EPA does not enforce them. "They are established as guidelines to assist public water systems in managing their drinking water for aesthetic considerations, such as taste, color, and odor. These contaminants are not considered to present a risk to human health at the SMCL."5

Every one of these was written for public water systems. "EPA does not regulate or provide recommended standards for private wells."6 Well owners use the same numbers as a yardstick.

Units

Units are where a result is easiest to misread. A lead result of 0.005 and one of 5 can be the same amount in two units.

UnitSame asTo convert
mg/L (milligrams per liter)ppm, parts per million47mg/L × 1,000 = µg/L. Arsenic at 0.01 mg/L is 10 µg/L.
µg/L or ug/L (micrograms per liter)ppb, parts per billion8µg/L ÷ 1,000 = mg/L. Manganese at 120 µg/L is 0.12 mg/L. µg/L × 1,000 = ng/L.
ng/L (nanograms per liter)ppt, parts per trillion2ng/L ÷ 1,000 = µg/L, and ÷ 1,000,000 = mg/L. PFOA at 4 ng/L is 0.004 µg/L.
gpg (grains per gallon)Hardness only9gpg × 17.1 = mg/L. 10 gpg is about 171 mg/L. Penn State Extension rounds it to 17.
Nitrate "as N" or "as nitrate"Two ways to report the same nitrate10As nitrate ÷ about 4.5 = as nitrogen. 45 mg/L as nitrate is EPA's 10 mg/L as nitrogen.

The nitrate factor comes from Penn State Extension's line: "Supplies should not contain more than 45 mg/l of nitrate or 10 mg/l of nitrate-nitrogen."10 The grain factor is the one our results checker uses (64.79891 mg per grain ÷ 3.785412 L per gallon).

A worked example

This is a made-up well report, not anyone's real result. It shows how to read each line.

TestResultUnitsLimitRLQualifier
Nitrate as N4.2mg/L100.5
Arsenic<1µg/L101U
Lead0.003mg/L0.015 (action level)0.001
Manganese0.12mg/L0.05 (secondary)0.01H
PFOA2.1ng/L41.8J
Total coliformPresentP/AAbsent
  1. Nitrate. 4.2 is under 10. It is above 3, which the Minnesota Department of Health says can point to a human-made source.11 Nitrate results.
  2. Arsenic. Not found at or above 1 µg/L. The reporting limit sits below the 10 µg/L limit, so this line does answer the question. Arsenic results.
  3. Lead. 0.003 mg/L is 3 µg/L, or 3 ppb. That is under the 15 ppb action level, but EPA's goal for lead is zero. Lead results.
  4. Manganese. 0.12 mg/L is 120 µg/L, over EPA's 0.05 mg/L taste and stain guideline, and the lab flagged it H. Minnesota's health department calls 100 µg/L or less safe for a baby who drinks tap water.12 Manganese results.
  5. PFOA. The J means the lab saw it but 2.1 is an estimate below its reporting limit. It is under EPA's 4 ppt. PFAS results.
  6. Total coliform. Present means bacteria got into the water. Ask the lab whether E. coli was tested. Coliform results.

EPA limit for public water systems, shown for reference. Private wells are not regulated.

Answers by test

If a result means you need a filter, softener, or treatment system, see help paying for water treatment.

Common questions

Why does my report have pages of results I did not order?

Most are the lab's quality control checks, not your water. Maine DEP says each report includes several pages of quality control information that can easily be confused with actual sample results. If you tested for volatile organic compounds, the Rhode Island Department of Health says chemicals labeled surrogates are not results from your water sample.

What is the chain of custody form?

It is the record of your sample's trip to the lab. The Rhode Island Department of Health says the chain of custody form shows exactly who handled your sample and when.

Who can explain my report to me?

Call the lab. The Rhode Island Department of Health says certified laboratories have someone on staff called an Interpreter whose job is to talk with you about your results. Your county or state health department can help too.

Does a result under the limit mean my water is safe?

It means the result is under the limit for that one thing. EPA's health goal is lower than the limit for some contaminants: zero for lead and arsenic. A test only covers what the lab looked for, so a report with no flags says nothing about tests that were not run.

Sources

  1. Rhode Island Department of Health, Reading Your Water Analysis Report
  2. New York State Department of Health, Understanding Your Lab Report
  3. Maine Department of Environmental Protection, How to Read and Interpret my PFAS Laboratory Data Report
  4. EPA, National Primary Drinking Water Regulations
  5. EPA, Secondary Drinking Water Standards: Guidance for Nuisance Chemicals
  6. EPA, Meaningful and Achievable Steps You Can Take to Reduce Your Risk
  7. Montana State University Extension, Understanding Your Test Results
  8. Minnesota Department of Health, Arsenic in Drinking Water
  9. Penn State Extension, Water Softening
  10. Penn State Extension, Nitrates in Drinking Water
  11. Minnesota Department of Health, Nitrate in Drinking Water
  12. Minnesota Department of Health, Manganese in Drinking Water

Checked November 15, 2026.